Grass Valley K2 Storage System Instruction Manual v.3.2 Nov.18 2008 User Manual

Page 500

Advertising
background image

500

K2 Storage System Instruction Manual

July 15, 2008

Chapter 13 Administering and maintaining the K2 Storage System

The Bind dialog box opens showing all unbound disks for the controller listed in
the Available Disk list.

2. Leave

Full Bind

unchecked. Refer to the previous section

“About full/background

bind”

.

3. In the

Bind TYPE

drop down box, select the RAID type. Refer to the installation

chapter earlier in this document for your level of storage system for specific
instructions regarding RAID 1, 3, 5, and 6.

4. In the Available Disks box, select contiguous disks at the top of the list as

appropriate for the RAID type. (TIP: Use ‘shift-click’ or ‘control-click’ to select
disks.)

5. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive LED to flash.

6. Click

OK

to close the Bind dialog box and begin the binding process. The Progress

Report dialog box opens, showing the status of the binding process.

7. Close the Progress Report and repeat these steps for other unbound disks.

8. Upon 100% completion, click

Close

in Progress Report window.

9. Restart the K2 Media Server.

Advertising