Grass Valley Kayenne v.3.0 User Manual

Page 358

Advertising
background image

358

KAYENNE — User Manual

Section 3 — System Operation

This allows you to see what switcher sources will be affected by a register
recall, and what the router sources and destinations will be after the recall.

When

Preview

is turned off, the left pane returns to displaying the current

status, including any previously set enables.

To Learn an R-MEM Register:

1.

Enable the switcher sources to be affected by R-MEM in the left pane.
Selected switcher source buttons are green on the left. Only the selected
sources will be saved to the R-MEM. You can use the

Enable All

button to

select all or none of the switcher sources (toggle).

2.

If you want the register to use Auto Recall, touch the

Auto Recall

button

so its indicator illuminates.

3.

Touch the

Learn

button in the Mode pane.

4.

Touch the numbered Bank and Register buttons in the right pane to
save the information to the selected register. Touch the bank button first
if you are saving to a different bank. If the desired bank is already
selected, you can touch just the Register button.

To Recall an R-MEM Register

1.

Make sure the Preview mode button is not selected.

2.

Turn the

Auto Recall

button on or off to control how the register is

recalled.

3.

Touch the Bank and Register buttons for the desired register. Touch the
bank button first if you are recalling from a different bank, or just touch
the Register button if in the same bank.

a.

If the

Auto Recal

l button is on, the sources selected when the register

was saved (with

Auto Recall

on) will be changed to the R-MEM

values of that register. If

Auto Recall

was not on when the register was

saved, the currently selected switcher sources will be changed.

b.

If the

Auto Recall

button is off, the sources currently selected in the

Switcher source pane will be updated with the R-MEM values of
that register.

Note

A switcher source that is currently on-air with an On Air protection status
cannot be changed by an R-MEM recall. Either place the source off-air or
select a different protection status to change the switcher source selection.

Advertising
This manual is related to the following products: