7 installation considerations checklist, Model nga 2000 hfid – Emerson Process Management 760004-A User Manual

Page 29

Advertising
background image

Instruction Manual

760004-A

February 2002

Rosemount Analytical Inc. A Division of Emerson Process Management Description and Specifications 2-9

Model NGA 2000 HFID

2-7 INSTALLATION CONSIDERATIONS CHECK-

LIST

Verify the following:

• The Analyzer’s location should

be:

Clean

A well ventilated area

weatherproofed

Non-hazardous

Vibration-free

Have stable ambient temperature

• The gas cylinders should be

equipped with a clean, hydrocar-
bon free two stage regulator and
shut off valve.

• All external tubing, regulators,

valves, pumps, fittings, etc. are
clean.

• The correct fuel type is being

used.

• The THC content of the supply

gases are compatible with the
analysis range.

• The calibration background

gases are similar to the sample.

• The purge air out, burner ex-

haust, and bypass are vented to
atmospheric pressure. The pres-
sure should be constant.

• The burner exhaust tube must be

slanted down a minimum of 6
degrees from horizontal.

• The bypass line connection must

be slanted down a minimum of 6
degrees from horizontal for
drainage of water condensation.

• If required, thermal insulation

around the bypass fitting to pre-
vent condensation in the bypass
restrictor.

• If required, thermal insulation for

the sample inlet connection to
minimize the cold spot.

• The heated line is at the correct

temperature.

• The sample, zero, and span

gases are at the correct tem-
perature.

• The heated line to have over

temperature protection.

• The sample, bypass, and burner

exhaust tubing material must
handle high temperature and
have thermal insulation to protect
from burns.

• The purge air out tubing to be

3/8 inch and less than 4 feet in
length.

• All external gas connections

have been leak checked.

• The dead volume for external

sample and fuel lines have been
minimized.

• The stainless steel tubing used

for the fuel and sample lines is
clean.

Advertising