Electrical Connection

SMA Solar Technology AG

40

WB5A_6A-IA-IEN114540

Installation Manual

• PowerGuard

This setting can be carried out if the entire small wind turbine system consists of 3 inverters only
and the asymmetric load is to be limited to 4.6 kVA in case of failure.

– If one of the 3 inverters indicates a line voltage fault or a device fault and stops feeding

in, the other two inverters automatically limit their power to 4.6 kVA.

5.5.2 Cabling

Cable Requirements

To connect the SMA Power Balancer, use a "LiYCY" cable with the following structure:

• Indoors: LiYCY 2 x 2 x 0.25
• Outdoors: Li-2YCYv 2 x 2 x 0.25

Differing asymmetric load limit for Italy
In inverters configured to country standard DK 5940, the asymmetric load is limited to
6 kVA.

Object Description
A

Flexible insulation

B

Shielding

C

Twisted pair 2 (2 x 0.25 mm

2

)

D

Twisted pair 1 (2 x 0.25 mm²)