2 setting off-grid operation, Setting off-grid operation – SMA WB 5000A-11 Installation User Manual

Page 46

Advertising
background image

Electrical Connection

SMA Solar Technology AG

46

WB5A_6A-IA-IEN114540

Installation Manual

5.7.2 Setting Off-Grid Operation

To operate the inverter in an off-grid system with Sunny Island, you must set the inverter via the
"Default" parameter to off-grid operation ("OFF-Grid") operation.
You have several possibilities to set the inverter to off-grid operation:

• Setting via Sunny WebBox

or

• Setting via Sunny Data Control or Sunny Explorer

DANGER!
Danger to life due to high voltages in the event of outage of the power
distribution grid

If you set the inverter to off-grid operation, it does not fulfill any country-specific standards
or guidelines. If there is a power distribution grid outage, there will consequently be a
danger of back-feed.

Never operate the inverter directly on the power distribution grid when set to off-grid

operation.