9 troubleshooting, 1 blink codes, Troubleshooting – SMA WB 5000A-11 Installation User Manual

Page 65: Blink codes

Advertising
background image

SMA Solar Technology AG

Troubleshooting

Installation Manual

WB5A_6A-IA-IEN114540

65

9 Troubleshooting

If the inverter displays blink codes which differ from those described below, contact the
SMA Service Line.
In the user manual provided, you will also find a description of the display messages during operation,
status messages and measurement channels.
Do not try to carry out repairs other than those described here. Instead, use the
SMA Solar Technology AG 24-hour replacement service (the inverter will be ready for dispatch and
at the forwarding agency within 24 hours) and repair service.

9.1 Blink Codes

Green

Red

Yellow

Status

flashing

flashing

flashing

OK (startup phase)

permanently on

off

off

OK (feed-in operation)

permanently on

off

ground fault or varistor
defective

permanently on

OK (initialization)

flashing quickly
(3 x per second)

off

off

OK (stop)

permanently on

off

ground fault or varistor
defective

flashing slowly
(1 x per second)

off

off

OK
(waiting, grid monitoring)

goes off briefly
(approx. 1 x per second)

permanently on

off

ground fault or varistor
defective

off

off

OK (derating)

off

off

off

OK (night-time deactivation)

on / flashing

Fault

permanently on

off

ground fault or varistor
defective

on / flashing

ground fault or varistor
defective and disturbance

Advertising