4 fault detection – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 132

Advertising
background image

Digital Operator Display

Fault Name

Cause

Possible Solution

Control circuit is damaged.

• Cycle power to the drive.

Refer to Diagnosing and Resetting Faults on page

149

.

• If the problem continues, replace the drive.

Digital Operator Display

Fault Name

CPF23

PWM Feedback Fault
PWM feedback error.

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

CPF24

Drive Capacity Signal Fault
Entered a capacity that does not exist. (Checked when the drive is powered up.)

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

EF0

MEMOBUS/Modbus Communication External Fault
An external fault condition is present.

Cause

Possible Solution

An external fault was received from

the PLC with other than H5-04 = 3

“alarm only” (the drive continued

to run after external fault).

• Remove the cause of the external fault.
• Remove the external fault input from the PLC.

Problem with the PLC program.

Check the PLC program and correct problems.

Digital Operator Display

Fault Name

EF1

External Fault (input terminal S1)
External fault at multi-function input terminal S1.

EF2

External Fault (input terminal S2)
External fault at multi-function input terminal S2.

EF3

External Fault (input terminal S3)
External fault at multi-function input terminal S3.

EF4

External Fault (input terminal S4)
External fault at multi-function input terminal S4.

EF5

External Fault (input terminal S5)
External fault at multi-function input terminal S5.

5.4 Fault Detection

132

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising