Cooling Fan Replacement

The cooling fan is installed on the top of the drive. The cooling fan can easily be replaced

without tools or removal of the drive or enclosure parts.

WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to

comply can result in serious personal injury. Before servicing the drive, disconnect all power to the equipment.

The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED

will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute

after all indicators are OFF and measure the DC bus voltage level to confirm safe level.

CAUTION! Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or moderate

injury. Shut off the power to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes

and ensure the heatsink has cooled down.

n

Removing the Cooling Fan

1.

Depress the right and left sides of the fan cover tabs and pull upward. Remove the
fan cover from the top of the drive. The following figure illustrates a drive with a single
cooling fan.