b2: DC Injection Braking

Use b2 parameters to configure DC Injection Braking operation

b2-02

DC Injection

Braking

Current

Sets the DC Injection Braking current as a percentage

of the drive rated current.

0 to 75 50%

O

18A

b2-03

DC Injection

Braking Time/

DC Excitation

Time at Start

Sets DC Injection Braking time at start. Disabled

when set to 0.00 seconds.

0.00 to

10.00

0.00

s

O

18B

b2-04

DC Injection

Braking Time

at Stop

Sets DC Injection Braking time at stop.

When b1-03 = 0, this parameter sets the amount of

DC Injection time applied to the motor at the end of

the decel ramp. Disabled when set to 0.00.

0.00 to

10.00

0.50

s

O

18C

u

C: Tuning

C parameters are used to adjust the acceleration and deceleration times, S-curves, slip and

torque compensation functions and carrier frequency selections.

No.

Name

Description

Range Def. Mode Addr.

Hex

Pg.

C1: Acceleration and Deceleration Times

Use C1 parameters to configure motor acceleration and deceleration.

C1-01

<1>

Acceleration

Time 1

Sets the time to accelerate from 0 to maximum

frequency.

0.0 to

6000.0

10.0

s

S

200

93

C1-02

<1>

Deceleration

Time 1

Sets the time to decelerate from maximum frequency

to 0.

S

201

93

C1-03

<1>

Acceleration

Time 2

Sets the time to accelerate from 0 to maximum

frequency when Accel/Decel times 2 are selected by

a digital input.

O

202

93

C1-04

<1>

Deceleration

Time 2

Sets the time to decelerate from maximum frequency

to 0 when Accel/Decel times 2 are selected by a

digital input.

O

203

93

C1-09 Fast-Stop

Time

Sets the time to decelerate from maximum frequency

to 0 for the multi-function input fast-stop function.

Note: This parameter is also used by selecting “Fast-

Stop” as a Stop Method when a fault is detected.

O

208

C2: S-Curve Characteristics

Use C2 parameters to configure S-curve operation.