Operation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

high temperatures. For all loading, adjustment or

ash cleaning operations, use the insulated glove

provided.

Never leave children unattended near the insert

when it is in use.

The risk of burns from contact with hot surfaces

is very high.

In the event of poor weather conditions for

insert use (low pressure, moderate

temperatures, wind) back draught may occur in

the chimney flue. If this occurs, use a small

quantity of paper to heat the chimney flue and

restore normal draught. Afterwards, proceed

with normal product lighting.

5.4. FORCED VENTILATION OPERATION for the

SMARTBOX MODELS

The insert is equipped with two internal fans for forced propagation of

the air inside the cavities of the product. The fans are internally

mounted on the lower part of the insert structure.
The flow of hot air created by these fans is very slight in order

to keep the temperature of the air coming out of the outlet

very high and promote convection heating.
Using the control button located on the lower front panel

(figure 10), it

is possible to select the desired operation mode:

• Button on I

= MANUAL operation

• Button on II = AUTOMATIC operation.

IT IS NOT POSSIBLE TO SWITCH THE VENTILATION

OFF IF THE INSERT IS ON; this is to prevent high

temperatures from damaging the structure.

5.4.1.

Manual operation

When the switch is positioned on I, the fans are always on, regardless

of whether or not there is a fire inside the mouth of the insert.
To switch the ventilation off, when the fire is out, the switch must be

positioned on II; in fact, in this case the internal probe, if it is not at

temperature (~50°C), will not allow operation of the fans.

5.4.2.

Automatic operation

When the switch is positioned on II the fans switch on/off exclusively

when the temperature of the probe is higher/lower than

50/60°C.