Chapter 5

INSTALLATION AND USE MANUAL

page

31

Operation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

The probe has a high setting because it is designed to operate as a

probe for switching off the ventilation rather than a probe for

lighting. In fact, it is more convenient that the fans switch off

automatically when you are not near the insert rather than at the

beginning when it is still carrying out the initial lighting.

The temperature probe is located behind the On button; it is easily

accessible and can be checked by disassembling the front panel

(SmartBox) or taking off the fan box (Climasystem) by first removing

the screws that secure it.

To check that the probe works properly, position the button

on II, heat the probe with a hair dryer and wait for the fans

to switch off. In this manner you can check that the probe is

intact.
Never perform this check by subjecting the probe

directly to open flames (cigarette lighter, matches,

etc.) since this could irreparably damage the probe.

If the reaction times of the probe are too long, then you should check

why the structure takes a long time to increase its temperature.

Normally this phenomenon is caused by unsuitable wood or wood with

a low heat yield (see section

“4.10 Choice of fuel”) or because the

performance of the chimney flue does not allow suitable discharge of

the fumes and a correct combustion.

5.5. SMARTBOX F80 VN NATURAL VENTILATION

The insert can also operate by natural convection, which means that

the flow of hot air can pass through the entire structure even without

the aid of fans. The Smartbox F80VN maintains as a hot air outlet the

two fins located above the fire door

(figure 6) from which a natural air

flow will emerge at high temperatures that will be uniformly dispersed

throughout the room.

5.6. FORCED VENTILATION OPERATION for the CLIMASYSTEM MODELS

The only substantial difference between the ventilation of the

Climasystem and that of the Smartbox is represented by the fact that

the Climasystem model has three fans which are more powerful and

that the button has three positions instead of two.
The operating concept, on the other hand, is the same for the

two models.

• Position I

= MANUAL operation

• Position 0

= OFF

• Button on II = AUTOMATIC operation.

5.7. FORCED VENTILATION OPERATION for the SUPERCLIMA MODELS

5.7.1. FC 715 control unit operation

The device allows the speed of the fan, which is controlled by the radio

remote control, to be regulated in one of two modes:

Climasystem ventilation box setscrew