3�2 Performance Monitoring

To monitor different sized inverters, the Solar-Log™ normalized the value from every inverter to 1 kWp.

This is based on the amount of generator power set in

Configuration | Devices | Configuration

.

The generator power is equivalent to 100% and the value here is normalized to 1 kWp.

Example plant:

Fig.: Performance Monitoring: Example plant with two inverters

Inverter 1, Inverter 1 house

Inverter 2, Inverter 2 house

Generator Power:
25* 220W (modules) = 5500 Wp

Generator Power:
15* 220W (modules) = 3300 Wp

Module Field 1

Module Field 1

The Solar-Log™ compares all of the inverters that are located in the same module field.

Settings for the module fields are under

Configuration | Devices | Configuration

.