5�4�2 the meaning of the values in the overviews – Solare Datensysteme Solar-Log User Manual

Page 92

Advertising
background image

92

Operating the Solar-Log 500 and 1000 via the Display

5�4�2 The meaning of the values in the overviews

The following table contains the values and their meaning in alphabetical order.

Name

Unit

Meaning

CO

2

to

The amount of carbon dioxide emissions
that have been avoided based on the power
output.

Y-current

kWh

The current yield for the selected period

Yield Current/
Target

%

The current value displays the ratio of the cur-
rent yield to the target yield for the selected
period.

Y-max

kWh

The maximum yield for the selected period.

Y-min

kWh

The minimum yield for the selected period.

Y-avg

kWh

The average output for the selected period.

Energy

kWh

The total output for the day

Y-target

kWh

The Solar-Log™ runs a forecasting statistics
function that specifies a certain target value
for each month. If the target value or higher
has been achieved, the forecasted output has
been produced.

Yspec

Wh/Wp

The energy yield divided by the maximum
power. This value is a good reference value
when comparing plants.

Pac

Watt

Current amount of feed-in power P on the AC
side.

Pdc

Watt

Current amount of feed-in power P on the DC
side (Solargenerator) If only one multi-string
inverter has been selected, the individual
strings are displayed separately.

P-max

Watt

Maximum output for the day.

EF

%

The current efficiency from the generator
power and feed-in power. The manufacturer's
specification on the inverter's efficiency can
be checked here.

Advertising