Ericsson EDACS LBI-39077 User Manual

Page 37

Advertising
background image

DATA LINK TO GTI UNITS

LBI-39077

37

number shown in the Baud Rate field is not 1200, press the Enter key to display a second pop-up window (to the
right of the first) giving you a selection of baud rates. Select (highlight) 1200 and press the Enter key to move on to
the PC Comm Port field back in the SYSTEM CONFIG window. Type in the number of the serial COM port you
will use, and press the Enter key. The System Configuration screen, showing the INT_MODEM pop-up window and
the second pop-up window, is shown in Figure 29.

EDACS GTI Configurator/Database Manager V1.3 (SUPERVISOR mode)

ÉÍINDEX ННННННННННННННННННННННННННННН» ÚÄSYSTEM_CONFIGÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

ºNum ____System Name_____ Country Nodº ³ System Number: [002] ³

º001 SHARP TOP USA 002º ³ System Name: [HIGH PEAK ]³

º002 HIGH PEAK USA 001º ³ ³

º003 APPLE ORCHARD USA 002º ³ Country: [USA ] ³

º004 CHANDLERS USA 001º ³ Node Number: [001] ³

º º ³ Node Name: LYNCHBURG ³

º º ³ ³

º º ³ System Access:I ... PC Comm Port:1³

º º ³ UsÚÄINT_MODEMÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

º º ³ Di³ Phone #:9486563ЪДДДД¿ ³

ИНННННННННННННННННННННННННННННННННННН¼ ³ Di³ Baud Rate:1200 ³300 ³ ³

³ MiÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij1200³ДДДДДДДДДДДДЩ

ÉÍHELPÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»³ Should InterconnectÀÄÄÄÄÙnue, ³

ºSelect item with arrow keys and º³ when billing data is lost: Y ³

ºpress ENTER/RETURN. º³ Narrowband - 12.5 kHz?: N ³

ºEsc key exits. º³ Edit Voice Prompts:Y ... ³

º º³ Edit Dial Plan Table:N ... ³

ºDel key deletes field and exits. º³ Enable Auto Retrieve Billing:N ... ³

º º³ Create Date: 08/30/94 ³

º º³ Alter Date: ³

º ºÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

ИНННННННННННННННННННННННННННННННННННННН¼

Figure 29 - System Configuration Screen with Internal Modem Pop-up Window

4.

Select (highlight) the Monitor operation from the Comm group in the Main Menu screen and press the Enter key. A
new screen then replaces the Main Menu screen. Select (highlight) the desired system from the INDEX window in
this new screen and press the Enter key. The INDEX window then disappears and a STATUS window appears
giving you the ongoing status as the GTI Configurator attempts to establish contact with the GTI unit through the
local RS-232 connection you have just made. Initially this STATUS window will show the following two statements:
“Connecting to system....” and “Requesting unit type...”. If the GTI Configurator does not receive a response from
the GTI unit, the STATUS window will show the following additional statement: “ERROR: No response, resending
pkt.”. Each time the GTI Configurator tries and fails to establish contact, the STATUS window will show the
following additional statement: “ERROR: No response, resending pkt.”. If the GTI Configurator fails to establish
contact with the system after three attempts, the STATUS window will show the following additional statements:
“ERROR: Exceeded packet retries”, “Unit never detected”, “Logically Disconnected”, and (after a pause) “Fully
Disconnected”. If the GTI Configurator establishes contact with the system, it will briefly (if you blink you will miss
it) show the following two additional statements: “CONNECTED!” and “Ready to process commands”, and then
display the Interconnect Monitor screen. A sample Interconnect Monitor screen is shown in Figure 27.

5.

The presence of the Interconnect Monitor screen means that the communications path is OK. You may now use it to
transfer user database parameters (such as System Config, Telco Config, and DID User Config information) to the
system, retrieve billing files from the system, and balance hybrids and set levels in the system. For more information
about these specific operations, see their respective sections later in this manual.