DATABASE

LBI-39077

43

EDACS GTI Configurator/Database Manager V1.3 (SUPERVISOR mode)

ÉÍINDEX ННННННННННННННННННННННННННННН» ÚÄSYSTEM_CONFIGÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

ºNum ____System Name_____ Country Nodº ³ System Number: [001] ³

º001 SHARP TOP USA 002º ³ System Name: [SHARP TOP ]³

º002 HIGH PEAK USA 001º ³ ³

º003 APPLE ORCHARD USA 002º ³ Country: [USA ] ³

º004 CHANDLERS USA 001º ³ Node Number: [002] ³

º º ³ Node Name: BEDFORD ³

º º ³ ³

º º ³ System Access:L ... PC Comm Port:1³

º º ³ Use Auto Time Set?: Y ... ³

º º ³ Disconnect on 2nd Dial Tone:Y ³

ИНННННННННННННННННННННННННННННННННННН¼ ³ Dial Tone Required:Y ... ³

³ Min. Call Time to Store: 020 ³

ÉÍHELPÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»³ Should Interconnect continue, ³

º º³ when billing data is lost: Y ³

ºEdit: press ENTER/RETURN/<ÄÙ º³ Narrowband - 12.5 kHz?: N ³

º º³ Edit Voice Prompts:Y ... ³

ºGuide Window: F1 º³ Edit Dial Plan Table:N ... ³

º º³ Enable Auto Retrieve Billing:N ... ³

ºDone: Esc º³ Create Date: 07/28/94 ³

º º³ Alter Date: 08/26/94 ³

º ºÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

ИНННННННННННННННННННННННННННННННННННННН¼

Figure 32 - System Configuration Screen

If a system is currently configured, you must select a specific system in the INDEX window before you can view or edit its
user data fields. The INDEX window shows four user data fields for up to nine systems at a time. Use the Page Down or Page
Up key to jump ahead or back nine systems at a time. Each of the four user data fields shown in the window can be used to
sort the data file. Use the left or right arrow key to select a field to sort. Use the up or down arrow key to select the desired
system. The current configuration for that system will then be displayed in the SYSTEM_CONFIG window. To edit the
current configuration, move the cursor to the SYSTEM_CONFIG window by pressing the Enter key. (Press the Esc key once
if you need to return to the INDEX window.) The SYSTEM_CONFIG window contains the following user data fields:

System Number - This three-character field is used to identify the system. It will also be used to identify the Telco
and DID User files for the system. Enter a different three-digit number (from 001 to 255) for each system. (Default =
blank)

System Name - This field is also used to identify the system, but is not required. (A name is usually easier to
remember than a number.) Enter the name of the system (up to 20 characters). (Default = blank)

Country - This field is used to adjust certain internal telco parameters that may vary from country to country. If you
press the Enter key when the cursor is in this field, a pop-up window will appear displaying a list of countries from
which you may make a selection. Use the arrow keys to select the country, then press the Enter key. (Default = USA)

Node Number - This field is used in multi-system networks to identify groups of systems. Enter a three-digit number
(from 001 to 255). (Default = blank)

Node Name - This field is also used to identify groups of systems, but is not required. Enter the name of the node
(up to 20 characters). (Default = blank)

System Access - This field is used to define which type of data link is being used to communicate with the GTI units
in the system. Enter L for a local RS-232 link, I for a remote link with internal GTI modem, or X for a remote link
with external GTI modem. (Default = L) If you enter an L, I, or X, a LOCAL, INT_MODEM, or EXT_MODEM
pop-up window will appear respectively, displaying the following two additional fields: