DATA LINK TO GTI UNITS

LBI-39077

41

EDACS GTI Configurator/Database Manager V1.3 (SUPERVISOR mode)

ÉÍINDEX ННННННННННННННННННННННННННННН» ÚÄSYSTEM_CONFIGÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

ºNum ____System Name_____ Country Nodº ³ System Number: [004] ³

º001 SHARP TOP USA 002º ³ System Name: [CHANDLERS ]³

º002 HIGH PEAK USA 001º ³ ³

º003 APPLE ORCHARD USA 002º ³ Country: [USA ] ³

º004 CHANDLERS USA 001º ³ Node Number: [001] ³

º º ³ Node Name: LYNCHBURG ³

º º ³ ³

º º ³ SYSTEM Access:X ... PC Comm Port:1³

º º ³ UsÚÄEXT_MODEMÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

º º ³ Di³ Phone #:9486563 ЪДДДДД¿ ³

ИНННННННННННННННННННННННННННННННННННН¼ ³ Di³ Baud Rate:2400 ³300 ³ ³

³ MiÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij1200 ³ДДДДДДДДДДЩ

ÉÍHELPÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»³ Should Interconnect ³2400 ³e, ³

ºSelect item with arrow keys and º³ when billing data i³4800 ³ Y ³

ºpress ENTER/RETURN. º³ Narrowband - 12.5 kH³9600 ³ ³

ºEsc key exits. º³ Edit Voice Prompts:Y³19200³ ³

º º³ Edit Dial Plan TableÀÄÄÄÄÄÙ ³

ºDel key deletes field and exits. º³ Enable Auto Retrieve Billing:N ... ³

º º³ Create Date: 08/30/94 ³

º º³ Alter Date: ³

º ºÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

ИНННННННННННННННННННННННННННННННННННННН¼

Figure 31 - System Configuration Screen with External Modem Pop-up Window

8.

The presence of the Interconnect Monitor screen means that the communications path is OK. You may now use it to
transfer user database parameters (such as System Config, Telco Config, and DID User Config information) to the
system, retrieve billing files from the system, and balance hybrids and set levels in the system. For more information
about these specific operations, see their respective sections later in this manual.

NOTE

If the GTI Configurator fails to make contact with the GTI unit, try the following:

Check the cabling (step 1).
Check the baud rate DIP switch section positions on the GTI unit (step 2).
Check the COM port selection.
Make sure your modems are powered on.
Check the number of the telephone line connected to the GTI unit.
Verify that the interrupt jumpers for the COM port are set right: IRQ4 for COM1 or IRQ3 for COM2.
See the Initialization Command String Change heading below.

Initial Command String Change

The GTI Configurator and the modem on the GTI Configurator side of the telephone exchange require an initial exchange of
data, or handshake. The default handshake parameters in the GTI Configurator have been set for a Hayes or Hayes-
compatible modem. If the modem you are using does not respond to the Hayes "ATZ" and "ATDT" commands, you may have
to change the initialization command string sent by the GTI Configurator to the modem. To change the initialization
command string, select (highlight) the Change PC Modem Parms operation from the Other group in the Main Menu screen,
and press the Enter key to display a new screen. In the STATUS window, type in the new initialization command string,
following the on-screen instructions.