+PORKTND

+PROFILE

46

PROG

START

*CC CHICK

14

CC CHICK

NOTES:

Any cooking parameter in any step of a program can be changed. However, once
saved, no step can be added or removed.

Factory Preset Programs (See Library of Preset Programs, page 39) CANNOT
be edited. However, they can be copied and saved as a custom program, and
then edited. See “Copying programs” below.

Copying programs

Preset programs can be copied and saved as custom programs and edited as
desired. IQT Logic programs with specific values can be copied and saved as
custom programs. They cannot be edited.

To copy Preset programs:

Press the IQT key and use the Central Dial to select the desired program to copy.
Each Preset program is preceded by an asterisk.

Press PROG/START once to activate program.

Press and hold IQT key until flashing (available) program number appears in
program display. You may now accept this number for use or select any other
available number using the Central Dial.

Press the IQT key. All displays go out, indicating that the Preset program has
been saved into the custom program memory. The Preset program name will
now appear in the program display WITHOUT the asterisk. Access, rename and
edit this program as desired, following the procedures above.

To copy an IQT Logic program:

Press the IQT key and use the Central Dial to select the desired IQT Logic
program to copy.

Follow procedures (pages 33-37 ) to enter required settings.

DO NOT Press PROG/START to confirm/activate.

Instead, press and hold IQT key until flashing program number appears in
program display. You may now accept this number for use or select any other
available number using the Central Dial.

Press the IQT key again. All displays go out, indicating that the IQT Logic
program has been saved into the custom program memory. The IQT program
name will now appear in the program display WITH the

+

. Access and rename

this program as desired, following the procedures above.

NOTE: IQT Logic programs, while appearing to contain many changes or steps are
nevertheless integral–they are NOT themselves composed of separate programming
steps that may be edited. They do not work this way. When in operation, they
respond with changes to real-time conditions in the cabinet. While these programs
cannot be edited, they MAY be inserted whole as an individual step in a custom
program.

Changes must be saved before moving to the next step of the program.