Model OFE/OFG-321,322,323,324



2-14. DRAIN MICROSWITCH

Upon turning the drain handle, the drain microswitch circuit

should open, cutting off the pilot flame. This will prevent the fryer

from heating while shortening is being drained from the frypot.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. The following check should be made to determine if the drain

microswitch is defective.

a. Remove the two screws securing the microswitch to the

drain rod valve bracket.


b. Remove wires from the switch.

c. Check for continuity across the two outside terminals of the

drain switch. If the circuit is open, the drain switch is
defective. The circuit should only be opened by pressing on
the actuator of the drain switch.

3. Replace switch in reverse order.





2-15. FILTER SWITCH


1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.