Henny Penny OFE/OFG-322 User Manual

Page 16

Advertising
background image

Model OFE/OFG-321,322,323,324



2-16. GAS CONTROL VALVE
ASSEMBLY
(Continued)

7. With the bracket dropped down, remove the two screws behind

the bracket securing the gas control valve to the bracket.





8. Install the new gas control valve in reverse order.





2-17. BLOWER MOTOR
ASSEMBLY

The blower motor assembly induces the draft for the burners. If the

blower motor fails, the air switch will fail to close, causing an

“E-20B” error code in the display.


1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.




2. Remove screws securing the two rear covers to the unit.







3. Remove the wire cover from the blower motor housing.







2-16