background image

Model OFE/OFG-321,322,323,324



2-8. PILOT / IGNITOR

The Henny Penny open fryer (gas) has electronic spark ignition

ASSEMBLY

that lights a standing pilot. The gap between the spark electrode

and the pilot hood should be set at 1/8 of an inch.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE,

BEFORE

STARTING

THIS

PROCEDURE,

MOVE

THE

MAIN

POWER

SWITCH

TO

THE

OFF

POSITION. DISCONNECT THE MAIN

CIRCUIT

BREAKERS

AT

THE

CIRCUIT

BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE

EXPLOSION

COULD

RESULT.

2. Remove the control panel as discussed in Complete Control

Panel Replacement Section.


3. Disconnect the pilot gas line fitting at the pilot assembly with

a ½ inch wrench.

4. With a Phillips head screwdriver, remove the two screws

securing the pilot assembly to the mounting bracket.


5. Remove the flame sensor wire from the flame sensor.

6. Follow the wire from the spark ignitor back to the module, and

remove wire from module.

7. After removing assembly from unit, pull the flame sensor out

of the bracket as discussed in section 6-7. Insert flame sensor
into new pilot/ignitor assembly.

8. Reinstall the new pilot/ignitor assembly in reverse order. Be

extremely careful not to cross thread the pilot gas line fitting.