5. Remove the bracket from the heat tube covering the high limit

bulb.

6. Straighten the capillary tube behind the pot wall.

7. Pull the high limit bulb through the retainers on the heat tube.

8. Remove the larger outside nut that threads into the pot wall.

9. Remove the defective high limit from the control panel area.

10. Insert new high limit into bracket and replace wires.

11. Uncoil capillary line, starting at capillary tube, and insert

through frypot wall.

To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must never be in such a position where
it could accidentally touch the electrical power terminals.

12. Insert capillary line through brackets on heat tube, and then

pull back through pot wall until capillary bulb is secure in
brackets.

13. Pull excess capillary line from pot and tighten nut into

frypot wall.

14. With excess capillary line pulled out, tighten smaller nut.

15. Replace bracket on heat tube covering the high limit bulb.

16. Replace front panel.

17. Refill frypot with shortening.