Henny Penny OFE/OFG-322 User Manual

Page 25

Advertising
background image

Model OFE/OFG-321,322,323,324



2-21. HIGH TEMPERATURE
LIMIT CONTROL
(Electric Units)

(Continued)

Be sure capillary bulb of high limit is located behind

capillary bulb of thermostat. Both capillary bulbs

and bulb holders should be positioned as not to interfere

with basket or when cleaning the frypot wall, or damage to

capillary

tube

could

result.


13. With excess capillary line pulled out, tighten smaller nut hand

tight, then ¼ turn with wrench.


14. Replace front panel.


15. Refill with shortening.



2-22. AUTOLIFT

1. Remove electrical power supplied to unit.

ACTUATOR (MOTOR)

REPLACEMENT

(if

applicable)

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


2.

Drain

shortening

from

frypot.


3. Remove baskets and using a large, flat-head screwdriver push

the clevis pin through basket hanger. Using pliers,

pull pin from assembly.




4. Remove rear cover.




606

2-25

Advertising
This manual is related to the following products: