Henny Penny OFE/OFG-322 User Manual

Page 22

Advertising
background image

Model OFE/OFG-321,322,323,324



2-19. HEATING

Checkout

(Power

Supplied)

CONTACTORS
(ELECTRIC ONLY)

(Continued)


To avoid electrical shock, make connections before

applying power, take reading, and remove power before

removing meter leads. The following checks are

performed with the wall circuit breaker closed and the

main

power

switch

in

the

ON

position.

1. Re-apply power to unit and turn POWER switch ON.


2. Using illustrations from previous page, check voltage as

follows:


Test Points

Results

From terminal 34 to 35

The voltage should read

From terminal 35 to 36

the same at each terminal

From

terminal

34

to

36


Replacement:

If either contactor is defective it must be replaced as follows:

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other controls will have

power.

1. Remove only the wires directly connected to the contactor being

replaced. Label the wires for replacement.

2. Loosen the screws securing the contactor bracket to the shroud.

3. Remove the contactor from the bracket.

4. Reinstall in reverse order.