Henny Penny OFE/OFG-322 User Manual

Page 24

Advertising
background image

Model OFE/OFG-321,322,323,324



2-21. HIGH TEMPERATURE

1. Drain the shortening from the frypot.

LIMIT CONTROL
(Electric Units)

(Continued)

2. Remove control panel.


3. Loosen small inside screw nut on capillary tube.


4. Remove capillary bulb from bulb holder inside the frypot.


5. Straighten the capillary tube.


6. Remove larger outside nut that threads into pot wall.


7. Remove the two screws that secure the high limit to the high

limit

bracket.


8. Remove the defective control from the control panel area.


9. Insert new control and replace screws.


10. Uncoil capillary tube, starting at control, and insert through

pot

fitting.

To avoid electrical shock or other injury, run the capillary

line under and away from all electrical power wires and

terminals. The tube must NEVER be in such a position

where it could accidentally touch the electrical power

terminals.

11. Carefully bend the capillary bulb and tube toward bulb holder

on

heating

elements.


12. Slip capillary bulb into bulb holder on heating elements.

Pull excess capillary line from pot and tighten nut into frypot

wall.



2-24