2-17. BLOWER MOTOR
ASSEMBLY
(Continued)


8. Using 3/8 inch nut driver, remove nuts securing blower to the

unit.

Pull

blower

from

unit.




9. Install new blower in reverse order.




2-18. HEATING ELEMENTS
(ELECTRIC ONLY)

Heating elements are available for 208 and 230 volts. Check

data

plate

to

determine

correct

voltage.



Checkout:

If the shortenings temperature recovery is very slow or at a slower

rate than required, this may indicate defective heating element(s).

An ohmmeter will quickly indicate if the elements are shorted or

open.

1. Remove electrical power supplied to the frypot to be worked on.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other controls will have

power.

2. Remove control panel.