Henny Penny OFE/OFG-322 User Manual

Page 2

Advertising
background image

Model OFE/OFG-321,322,323,324



2-3 HIGH TEMPERATURE
LIMIT CONTROL
(Continued)


3. Remove the two nuts securing the high limit bracket to the unit

and pull the bracket from the unit.

4. Remove the two screws securing the high limit to the bracket,

and remove the high limit from the bracket.

5. Remove the two electrical wires from the high temperature

limit control.

6. Manually reset the control, then check for continuity between

the two terminals after resetting the control. If the circuit is
open, replace the control, then continue with this procedure.
(If the circuit is closed, the high limit is not defective. Re-
connect the two electrical wires.)

Replacement:


To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker,

or

unplug

cord

at

wall

receptacle.

1. If the tube is broken or cracked, the control will open, shutting

off electrical power to the heat circuit. The control cannot be
reset, and it will continuously click when pushed.

2. Drain the shortening from the frypot and discard. A substance

in the tube could contaminate the shortening.

3. Remove the control panel.

4. Loosen small inside screw nut on capillary tube.





2-2