Henny Penny OFE/OFG-322 User Manual

Page 14

Advertising
background image

Model OFE/OFG-321,322,323,324



2-15. FILTER SWITCH

(Continued)

2. Remove the control panel above the switch.

3. Label and remove the wires from the switch. With test

instrument, check across the terminals of the switch with the

switch in the ON position, and then in the OFF position. With

the switch in the ON position, the circuit should be closed.

With the switch in the OFF position, the circuit should be open.

If the switch checks defective, replace it by continuing with

this

procedure.

4. With wires removed from the switch, push in on tabs on the

switch and remove switch from the panel.

5. Push new switch into panel and reconnect wires.




2-16. GAS CONTROL VALVE
ASSEMBLY

The gas control valve assembly controls the flow of gas to the pilot

and the main burner. The valve has two 24 volt coils, which are

regulated by terminals P and M on the valve. The C terminal is the

common terminal. For gas flow to the pilot, 24 VAC must be

present between the P and C terminals. For gas flow to the main

burner, 24 VAC must be present between the M and C terminals.

TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE,

BEFORE

STARTING

THIS

PROCEDURE,

MOVE

THE

MAIN

POWER

SWITCH

TO

THE

OFF

POSITION. DISCONNECT THE MAIN

CIRCUIT

BREAKERS

AT

THE

CIRCUIT

BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE

EXPLOSION

COULD

RESULT.

1. Remove control panel assembly.

2. Remove wires from gas control valve.


2-14

203

Advertising