When the network device on which the change in state has occurred is a server load balancer

Confirm the status of the server load balancer.
For details on how to confirm the status of the server load balancer, refer to "

11.4.3 Server Load Balancer Status Confirmation

".

-

When the network device on which the change in state has occurred is an L2 switch

Check the status of the L2 switch.
For details on how to confirm the L2 switch status, refer to "

11.4.4 L2 Switch Status Confirmation

".

See

For details on the operations (such as status confirmation) for network devices, refer to the manuals of network devices.

11.4.2 Firewall Status Confirmation

This section explains the confirmation procedure of firewall status.

11.4.2.1 When an L-Platform Using a Firewall is Identified

Use the following procedure to confirm the status of the firewall.

1.

In the orchestration tree, select the network device of a firewall under the L-Platform.

2.

Select the [Resource Details] tab, and click the link of [Preserved resource] of [Network Device] of [Basic Information of Network
Device].

The [Resource Details] tab of the network device is displayed.

3.

Confirm the displayed detailed information.

When the target network device is in a redundant configuration, confirm both the devices are in active status and standby status.

-

When there is a link of [Launch Network Device Web UI] in [Hardware Details]

a.

Click the link and start the firewall management screen.

b.

Check the event log, status (interface, system condition, and operation status), whether communication packets can pass
from the started management window, and the error detected by the firewall.

-

When there is no link of [Launch Network Device Web UI] in [Hardware Details]

Confirm the following information displayed in the Main Panel.

Basic Information - Device Status

The status of the firewall is displayed.
When the status is something other than "normal", it indicates that an error might have occurred.

Port Information - Link Status

The port status of the firewall is displayed.
When the status is something other than "up", unless changed intentionally by the infrastructure administrator, it indicates
that a port error might have occurred.

Additionally, check the status (system condition and operation status) and whether communication packets can pass by logging
in to the firewall directly, and check the error detected by the firewall.

4.

Confirm the status of the firewall.

-

When passing of communication packets is rejected by a firewall or an event log is output

The infrastructure administrator must confirm if the following items using auto-configuration are correct.

-

Scripts for configurations

-

Parameter files

- 105 -