Preinstallation preparation, Selecting location, Minimum clearance to combustibles – FMI BVC-50Y User Manual

Page 10: Framing

Advertising
background image

www.fmiproducts.com

122280-01E

10

Figure 6 - Rough Opening Dimensions

for Installing in a Wall

59

1

/

4

" (50")

58

1

/

8

"

30

1

/

8

"

(42", 50")

28

1

/

4

" (36")

67

1

/

8

"

51

1

/

4

" (42")

45

1

/

4

" (36")

SELECTING LOCATION

To determine the safest and most efficient

location for the fireplace, you must take into

consideration the following guidelines:
1. The location must allow for proper

clearances (see Figures 6 and 7).

2. Consider a location where fireplace will

not be affected by drafts, air conditioning

ducts, windows or doors.

3. A location that avoids cutting of joists or

roof rafters will make installation easier.

4. An outside air kit is available with this

fireplace (see Optional Outside Air Kit,

page 11).

MINIMUM CLEARANCE TO

COMBUSTIBLES

Back and sides of fireplace

1

1

/

2

" min.*

Front of fireplace

48" min.

Floor**

0" min.

Perpendicular wall to opening

12" min.

Top spacers

0" min.

Mantel clearances

see Mantels, page 11

Chimney outer pipe surface

1" min.

* Not required at nailing flanges
** See step 2 of Framing

WARNING: Do not pack re-

quired air spaces with insulation

or other materials.

FRAMING

1. Frame opening for fireplace using dimen-

sions shown in Figures 6 and 7.

2. If fireplace is to be installed directly on

carpeting, tile (other than ceramic) or any

combustible material other than wood

flooring, fireplace must be installed upon

a metal or wood panel extending full width

and depth of fireplace.

3. Set fireplace directly in front of this open-

ing and slide unit back until nailing flanges

touch side framing.

4. Check level of the fireplace and shim with

sheet metal if necessary.

5. Before securing fireplace to prepared

framing, ember protector (provided) must

be placed between hearth extension (not

supplied) and under bottom front edge

of fireplace to protect against glowing

embers falling through. If fireplace is to

be installed on a raised platform, a Z-type

ember protector (not supplied) must be

PREInStaLLatIOn PREPaRatIOn

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86.5" (36" Models)

61" (36" Models)

Maintain 1

1

/

2

"

Clearance

at Sides and

Back of Fireplace

1

1

/

2

" Clearance

Not Required at

Nailing Flanges

Figure 7 - Corner Installation

fabricated to fit your required platform

height. Ember protector should extend

under fireplace a minimum of 1

1

/

2

". Ember

protector should be made of galvanized

sheet metal (28 gauge minimum to pre-

vent corrosion.