Introduction – FMI BVC-50Y User Manual

Page 5

Advertising
background image

www.fmiproducts.com

122280-01E

5

IntRODuCtIOn

Models BBM-36(N,P)-TKA, BBM-42(N,P)-

TKA and BBM-50(N,P)-TKA are vented gas

appliances that use an electronic control

valve and electronic ignition system. A FMI

PRODUCTS, LLC venting system and vent

cap are not supplied but are required for

proper operation If a B-type venting system

is installed, transition pipe model BTC-B is

required. See venting instructions beginning

on page 12.

WARNING: This gas appli-

ance must not be connected to

a chimney flue servicing a solid

fuel burning appliance.

BEFORE YOU BEGIN

Before beginning the installation of your

appliance, read these instructions through

completely.

This FMI PRODUCTS, LLC appliance and

its approved components are safe when

installed according to this installation manual

and are operated as recommended by FMI

PRODUCTS, LLC. Unless you use FMI

PRODUCTS, LLC approved components

tested for this appliance,

YOU MAY CAUSE

A FIRE HAZARD!

The FMI PRODUCTS, LLC warranty will

be voided by and FMI PRODUCTS, LLC

disclaims any responsibility for the following

actions:

A) Modification of the appliance or any of the

components.

B) Use of any component part not approved

by FMI PRODUCTS, LLC in combination

with this appliance.

C) Installation and/or operation in a manner

other than instructed in this manual.

D) The burning of anything other than the

type of gas approved for use in this gas

appliance.

The installation must conform with local

codes or, in the absence of local codes, with

the current National Fuel Gas Code, ANSI

Z223.1/NFPA 54.

WARNING: Installation of this

appliance should be done by a

qualified service person.

NOTICE: This appliance is not

intended to be used as a primary

source of heat.

CAUTION: Do not connect

appliance before pressure test-

ing gas piping. Damage to gas

valve may result and an unsafe

condition may be caused.

The appliance and it’s individual shutoff valve

must be disconnected from the gas supply

piping system during any pressure testing of

that system at test pressures in excess of 1/2

psig (3.5 kPa).
The appliance must be isolated from the gas

supply piping system by closing its individual

manual shutoff valve during any pressure

testing of the gas supply piping system at

test pressures equal to or less than 1/2 psig

(3.5 kPa).
For the purpose of input adjustment two

pressure taps (for IN and OUT pressures)

are provided on the gas control valve for test

gauge connections to the appliance.