tROuBLEShOOtInG

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,

etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

Fireplace produces a clicking/

ticking noise just after burner

is lit or shut off

Fireplace produces unwanted

odors

Gas odor even when gas

control valve is off

Gas odor during combustion

Dark residue on logs or inside

of fireplace

POSSIBLE CAUSE

1. Metal expanding while

heating or contracting while

cooling

1. Fireplace burning vapors

from paint, hair spray,

glues, etc. (See IMPOR-

TANT statement above)

2. For propane/LP gas, low

fuel supply

3. Gas leak.

See Warning

statement at top of page

1. Gas leak.

See Warning

statement at top of page

2. Control valve defective

1. Foreign matter between

control valve and burner

2. Gas leak.

See Warning

statement at top of page

1. Air holes at burner inlet

blocked

2. B u r n e r f l a m e h o l e s

blocked

3. Improper venting or exces-

sive blockage

4. Excessive amounts of em-

bers and pan material

REMEDY

1. This is normal with most

fireplaces. If noise is ex-

cessive, contact qualified

service person

1. Ventilate room. Stop us-

ing odor causing products

while fireplace is running

2. Contact local propane/LP

supplier

3. Locate and correct all leaks

(see Gas Line Hook-Up,

page 17)

1. Locate and correct all leaks

(see Gas Line Hook-Up,

page 17)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Gas Line Hook-Up,

page 17)

1. Clean out air holes at burn-

er inlets. Periodically repeat

as needed

2. Remove blockage or re-

place burner

3. Have vent system inspect-

ed, including termination

cap. Remove any restric-

tions or obstruction

4. Clear excess embers until

a minimum gap of 1/2"

remains under grate