PREInStaLLatIOn PREPaRatIOn

Continued

6. Using screws or nails, secure fireplace to

framing through flanges located on sides

of fireplace.

WARNING: When finishing

appliance, do not overlap com-

bustible material onto the black

front face. Brick, tile or other

noncombustible materials may

be applied to the face provided

that any gap is between the

material used and the face is

caulked with a noncombustible

caulking.

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

Installation of an outside air kit should be

performed during rough framing of fireplace

due to the nature of it's location. Outside com-

bustion air is accessed through a vented crawl

space (AK4F) or through a sidewall (AK4).

See

Figure 39 on page 32 for instruction of

operating air kit.

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

3" (7.6 cm)

1

1

/

2

"

(3.8 cm) Max.

8"

6" (15.2 cm)

14"

12"

(22.9 cm)

Combustible
Materials

30°

Figure 9 - Mantel Clearances - Side View

(Cross Section)

Figure 8 - Outside Air Kit

Secure to Collars with Metal Tape, Screws

or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

MANTELS

A combustible mantle shelf maybe installed

a maximum 12" (22.9 cm) from the wall.

Figure 9 and Figure 10 on page 12 show

the minimum allowable distances from

various combustible mantle components

in relation to the fireplace opening.