VEntInG InStaLLatIOn

Continued

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of

a galvanized outer pipe, a stainless steel in-

ner flue pipe and a wire spacer. Pipe sections

must be assembled independently as chimney

is installed. When connecting chimney directly

to fireplace, inner flue pipe section must be

installed first with lanced side up. Outer pipe

section can then be installed over flue pipe

section with hemmed end up. Press down

on each pipe section until lances securely

engage hem on fireplace starter. The wire

will assure proper spacing between inner and

outer pipe sections.

Opening in collar around

chimney at top of fireplace must

not be obstructed. Never use

blown insulation to fill chimney

enclosure.

Continue to assemble chimney sections as

outlined, making sure that both inner and outer

pipe sections are locked together. When install-

ing double wall snap-lock chimney together, it

is important to assure joint between chimney

sections is locked. Check by pulling chimney

upward after locking. Chimney will not come

apart if properly locked. It is not necessary to

add screws to keep chimney together.

FIRESTOP SPACERS (V3600FS-8DM)

Firestop spacers are required at each point

where chimney penetrates a floor space.

Their purpose is to establish and maintain

required clearance between chimney and

combustible materials. When pipe passes

through a framed opening into a living space

above, firestop must be placed onto ceiling

from below as shown in Figure 14.

Figure 14 - Firestop Spacer with Living

Space Above Ceiling

Figure 15 - Firestop Spacer with Attic

Space Above Ceiling

If area above is a living space, install

firestop below framed hole.

If area above is an attic or insulated area,

install firestop above framed hole.

They also provide complete separation from

one floor space to another or attic space as

required by most codes. When double wall

pipe passes through a framed opening into

an attic space, firestop must be placed into

an attic floor as shown in Figure 15.