Venting installation – FMI BVC-50Y User Manual

Page 16

Advertising
background image

www.fmiproducts.com

122280-01E

16

Terminations/Spark Arrestor

Fireplace system must be terminated with

listed round top or chase terminations. In any

case, refer to installation instructions supplied

with termination. Terminations approved for

this fireplace are RT-8DM and RTL-8DM that

can be used for flashing or chase and ET-

8DM, ETO-8DM, ETL-8DM and ETLO-8DM

for chase style termination only. Figure 19

shows an RTL-8DM round top termination.

CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions

provided with the termination

being used.

Terminations with 16" slip pipe sections are

available. RTT-8DM and RTTL-8DM are

approved for flashing installations. When

needed, these adjustable terminations may

be used in combination with pipe assembly

to achieve correct chimney height.
Note: In rare instance there is a problem with

side driven rain or wind or chimney is not draft-

ing properly, an ADS-8DM (Anti-Draft Shield)

can be used with round terminations.

VEntInG InStaLLatIOn

Continued

Attach Bracket

Tabs to

Outer Pipe

(3 Places)

Secure with

Screws

RTL-8D

Level of

Flue Gas

Outlet

Caulk

Collar

Flashing

Underlap Shingles

Bottom Only

Figure 19 - Termination

Overlap

Shingles Top

and Sides

VENTING INSTALLATION USING 8"

B-TYPE VENTING SYSTEM

Transition pipe model BTC-8 and starter collar

are shown in Figure 20. Remove starter collar

and set aside. Slide transition pipe over vent

collar and attach with a minimum of 4 screws.

Replace starter collar over transition pipe and

attach using 4 screws located on leg stands.

To install b-vent piping, slide first piece of

b-vent over transition pipe and attach with

either a minimum of 3 screws or other means

approved by the vent manufacturer.

B-Vent Piping

Transition Pipe

Model BTC-8

Starter Collar

Vent Collar

Figure 20 - Installing Transition Pipe and

Starter Collar

CHECKING FOR PROPER VENTING

After completing and checking electrical, gas

and vent connections, follow the lighting in-

structions and allow the main burner to run for

approximately 5 minutes. Hold a lighted match

near the top edge of fireplace opening and play

it along entire length of opening (see Figure 21,

page 17). Proper venting should tend to draw

the flame or smoke into the appliance. Improper

venting or escaping of spillage of burned gas, is

indicated when the match flickers or goes out.
If the appliance is found to be improperly

venting, shut it off and notify your installer

or a qualified service agency to inspect the

venting system.

NOTICE: This appliance is

equipped with a vent safety

shutoff switch which will shut

down the appliance in the case of

a venting problem. Do not bypass

the vent safety switch. If the appli-

ance should shut down, contact a

qualified installer, service agency

or your gas supplier to have the

vent inspected before operating.