Installation – FMI BVC-50Y User Manual

Page 18

Advertising
background image

www.fmiproducts.com

122280-01E

18

IN

PILO

T

IN

OUT

VENT

TH

TP

TH

TP

InStaLLatIOn

Continued

Figure 25 - Connecting Incoming Gas Line to Flex Gas Line

Gas Shutoff

Valve

Flexible Gas Line

Do NOT Kink

1/2" NPT

Incoming

Gas Line

Note:

1) Wire connections not

shown for clarity

2) * 1/8" NPT Plugged

Tapping

Red Surface Indicates For

Propane/LP Use Only

Pilot

Adjustment

Inlet Pressure Tap

Outlet

Pressure Tap

3" Min.

(7.6 cm)

Side W

all

Of Applianc

e

Incoming

1/2" Gas Line

Permitted by

Local Codes

Sediment Trap

(Not Supplied)

Figure 24 - Sediment Trap

Figure 23 - Installing Gas Line

Gas Line

Opening

Equipment

Shutoff Valve Valve on

Module

CAUTION: Compounds used

on threaded joints of gas piping

shall be resistant to the action

of Liquefied Petroleum (LP or

propane) and should be applied

lightly to ensure excess sealant

does not enter the gas line.

WARNING: All gas piping

and connections must be tested

for leaks after the installation is

completed.

After ensuring that gas valve

is on, apply a commercial leak

detection solution to all con-

nections and joints. If bubbles

appear, leaks can be detected

and corrected.

Do not use an open flame for leak

testing and do not operate any

appliance if a leak is detected.

Complete your gas installation by connect-

ing incoming gas line with flexible gas line.

Secure tightly with wrench but

DO NOT

OVERTIGHTEN.