Operation – FMI BVC-50Y User Manual

Page 32

Advertising
background image

www.fmiproducts.com

122280-01E

32

OPERatIOn

Continued

COMBUSTION AIR KIT

MODEL AK4 (OPTIONAL)

The outside air kit lever is located at the left

and right hand sides of fireplace (see Figure

40). The vent can be installed through any

outside wall a minimum of three feet below

fireplace termination cap. Lifting lever up will

free the outside air door to open. Pulling lever

down will lock the door.

CAUTION: Air inlet ducts are

not to terminate in attic space.

Open Position

Closed Position

Figure 40 - Outside Air Kit Lever

TO TURN OFF GAS

TO APPLIANCE

1. Turn off wall switch or press OFF on hand-

held remote.

2. Turn off all electric power to appliance if

service is to be performed.

3. Fully open glass doors if installed.
4. Remove front hearth brick and control

access panel.

5. Turn gas control knob clockwise

to OFF. Do not force.

6. Replace front refractory brick access

panel.

7. Fully close glass doors if installed.