Analog audio outputs, Digital audio input, Digital audio output – Fostex FR-2 User Manual

Page 45

Advertising
background image

45

FR-2

Field Memory Recorder (Chapter 4: Basic connections)

Analog audio outputs

The [ANALOG OUT] jacks (unbalanced RCA) output -10 dBV analog audio signals.

Digital audio input

<Note>:

When receiving a digital source which contains FS information, the FR-2 makes

recording according to the FS of the digital source regardless of the [FS (kHz)] switch
setting.
When recording a digital source which does not contain FS information, the FR-2 makes
recording according to the [FS (KHZ)] switch setting.
When receiving a digital source which does not contain FS information and making the
unit “input monitor” (record-standby), “

DIG IN

” is shown in inverse video on the display.

Digital audio output

The digital audio signals can be output from the [DIGITAL OUT] connector in the
IEC 60958 (AES/EBU) or IEC 60958 (S/P DIF) format.
You can select the digital output signal format (AES/EBU or S/P DIF) using the
"Digital Out Type" menu item on the "Setup" menu in the MENU mode (the default
is "AES/EBU").
A balanced XLR-3-32 type (pin 2 hot) connector is used.

<Note>:

The FR-2 does not accept digital signals at 176.4 kHz and 192 kHz.

<Note>:

The [DIGITAL OUT] connector does not support digital signals at 176.4 kHz and

192 kHz.

<Note>:

During recording of analog audio, the FR-2 does not receive a digital input

signal.

The FR-2 accepts digital signals conformed to IEC 60958 (AES/EBU) or IEC 60958
(S/P DIF) format via the [DIGITAL IN] connector (XLR-3-31, pin 2 hot). During
recording, the FR-2 automatically detects the format of the digital source.

When the FR-2 receives a digital signal from the [DIGITAL IN] connector, PLL (Phased-
locked loop) activates and the FR-2 locks to the sync signal in the digital input
source.