Read command, Read command -80, 60 read command -80 – FUJITSU C150-E049-02EN User Manual

Page 113

Advertising
background image

3-80

M3099GX/GH OEM Manual

The transfer length specifies the length in bytes of the window
identifier list that shall be sent during the DATA OUT phase. A
transfer length of zero indicates that no data shall be transferred. This
condition shall not be considered as an error.

The window identifier list consists of zero or more window
identifiers each of which specifies a window to be scanned.

This command is mandatory when scanning in duplex mode by
sending window identifier 00h, 80h. When scanning in simplex
mode this command is not required but it can be available. In the
simplex mode, only 00h(front page) is specifiable.

READ Command

The READ command (Table 3.60) requests that the target transfer
data to this initiator.

Table 3.60 READ Command

Bit

Byte

0

1

2

3

4

5

6

7

8

9

7

6

5

3

2

1

0

Operation Code (28h)

Data Type Code

Reserved

Data Type Qualifier

Transfer Length

Control

Logical Unit Number

Reserved

4

(MSB)

(MSB)

(LSB)

(LSB)

#03.pm5

98.2.22, 1:33 PM

80