Separation pressure adjustment, Appendix c, Appendix c: separation pressure adjustment – FUJITSU C150-E049-02EN User Manual

Page 226

Advertising
background image

M3099GX/GH OEM Manual

C-1

SEPARATION
PRESSURE
ADJUSTMENT

1 Turn off the power switch.

Make sure that the hopper
table is at the bottom.

2 Open the upper transport unit.

(See page 4-2)

3 Disconnect the two relay

connectors on the roller ASY.

4 Push the two levers (green)

towards each other to dis-
engage with the upper locking
holes and lower down the two
levers until they engage with
the two levers locking holes.

APPENDIX

C

SEPARATION PRESSURE ADJUSTMENT

Adjust the separation pressure as follows:

WARNING
Wait at least 3 minutes after turning off the power before replacement.

ACHTUNG
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem
Austausch beginnen.

Roller ASY

Lever (green)

Power switch

Operator panel

Upper transport unit

Lever

Advertising