3-100

M3099GX/GH OEM Manual

One-byte messages consist of a single byte transferred during a
MESSAGE phase. The value of the byte determines which message is
to be performed as defined in Table 3.83 (See ANSI SCSI-2 6.6
Table 10). The implemented Message Codes by this scanner is Table
3.83.

Table 3.83 Message Codes

Code

00h

02h

03h

04h

05h

06h

07h

08h

09h

0Ch

80h+

80h+

***

others

Key:

Support

Message Name

COMMAND COMPLETE

SAVE DATA POINTER

RESTORE POINTERS

DISCONNECT

INITIATOR DETECTED
ERROR

ABORT

MESSAGE REJECT

NO OPERATION

MESSAGE PARITY ERROR

BUS DEVICE RESET

IDENTIFY

IDENTIFY

SYNCHRONOUS DATA
TRANSFER REQUEST

Reserved

Nefate ATN

Before last

ACK

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Direction

Init

M

O

O

O

M

O

M

M

M

O

M

M

O

Targ

M

O

O

O

M

M

M

M

M

M

O

M

O

In

In

In

In

In

In

In

Out

Out

Out

Out

Out

Out

Out

Out

M: Mandatory support, O = Optional support
In: Target to initiator, out = Initiator to target.
Yes: Initiator shall negate ATN before last ACK of message.
No: Initiator may or may not negate ATN before last ACK of

message. (see Attention Condition)

—: Not Applicable
***: Extended message (see Tables 3.84 and 3.85)
80h: Codes 80h through FFh are used for IDENTIFY messages.
(See Table 3.86).

#03.pm5