Request sense command (see ansi scsi-2 8.2.14), 27 request sense command -49 – FUJITSU C150-E049-02EN User Manual

Page 82

Advertising
background image

M3099GX/GH OEM Manual

3-49

INTERFACE

REQUEST SENSE Command (See ANSI SCSI-2 8.2.14)

The REQUEST SENSE command (Table 3.27) requests that the
target transfer sense data to the initiator.

Table 3.27 REQUEST SENSE Command

Bit

Byte

0

1

2

3

4

5

7

6

5

3

2

1

0

Operation Code (03h)

Reserved

Reserved

Allocation Length

Control

Logical Unit Number

4

Reserved

The sense data:
1) shall be available if a contingent allegiance condition exists for the

I_T_x nexus;

2) shall be available if other information is available in any field;
3) may be available if an unexpected disconnect occurred.

If the target has no other sense data available to return, it shall return
a sense key of NO SENSE and an additional sense code of NO
ADDITIONAL SENSE INFORMATION.

The sense data shall be preserved by the target for the initiator until
retrieved by a REQUEST SENSE command or until the receipt of
any other I/O process for the same I_T_x nexus. Sense data shall be
cleared upon receipt of any subsequent I/O process (including
REQUEST SENSE) to the same I_T_x nexus.

The sense data format for error code 70h(current errors) is
supported.

#03.pm5

98.2.22, 1:32 PM

49

Advertising