D-108 Owner's Manual (Saving and Loading Song Data)

90

External Digital Device (DAT or Adat)

DIGITAL IN

DATA OUT

D-108

AC IN

MIDI

SCSI

OUTPUT

INPUT

DATA

OPTICAL

8

7

6

5

1

2

3

4

ANALOG OUT

ANALOG IN

THRU

OUTPUT

INPUT

4

3

2

1

8

7

6

5

Saving the data using DATA OUT

* Restore the initial settings on the D-108.
* Set the same sampling rate on the external digital device and the D-108.

Connecting an external device

Connect DATA OUTPUT connector of the D-108 to the digital input connector on the external digital device.

<Note>
The D-108 has DATA OUT connectors for an S/P DIF digital signal (OPTICAL) and for an adat
digital signal. These connectors have the same shape but carry different information.

* If the external device has only COAXIAL type (RCA) digital I/O connectors, connect an optional COP-1
(optical/coaxial converter) to use an S/P DIF digital signal.

* Connecting both output and input connectors on the D-108 to the input and output connectors on the
external digital device respectively may generate a digital loop. Refer to “Connecting a digital mixer” on
page "50" for more information.

Setting up an external device

1.Set the same sampling rate to that of the D-108.

2.Select digital input on the external device so that the external device will accept a digital signal.

On some external devices, you may have to set up so that the external device will synchronize with the incoming
digital signal.

<Note>

If the external device does not accept the digital signal or if you notice digital noise, check the connection, cabling,
and the settings of the D-108 and the external device.

* Refer to the instruction manuals that came with any external digital device for details.

Executing the save operation

Use the “Save PGM?” menu in Setup mode.

* Output format available:

adat, DAT, SCSI (6)

* Programs available:

P01 - P99

* Track available:

When using an adat or DAT: Tracks 1-8, Tracks 1-16, Tracks 1-24, Tracks 9-16,
Tracks 9-24, Tracks 17-24;
When using a SCSI disk: All tracks will be automatically selected.

S/P DIF digital signal (or adat digital signal) from the DATA OUT jack of the D-108 is saved. The prerequisite
is that an E-IDE harddisk is used as a current drive.