C-14

Command Sets

Function

Command

Barcode Printing

Mnemonic

Function

Command

Remarks

DECBAR

Start or Stop Bar

ESC % SP 0

Start barcode

Codes

ESC % @

Stop barcode

DECSBCA

Select Bar Code

CSI Ps1 ; Pn2

Attributes

; . . . ; Ps9 ´ q

Parameters

Description

Values

Ps1

Bar Code System

0, 2 : Code 39
1 : Interleaved 2 of 5
4 : EAN 8
5 : EAN 13
7 : Codabar a/t
8 : Codabar b/n
9 : Codabar c/*
10 : Codabar d/e
11 : UPC-A
13 : Postnet
14 : Industrial 2 of 5
18 : Matrix 2 of 5

Pn2

Width of narrow bars

Supported values : 10 (default) -

in Decipoints

-15 - 20 - 25 - 30.
Not applicable to UPC, EAN and
Postnet systems.

Pn3

Width of quiet zones

Supported value : 180

in Decipoints

Pn4

Width of wide bars

Ignored. Set at 2.5 * Pn2.

in Decipoints

Pn5

Ignored

Pn6

Height of bars in

Min = 60

Decipoints

Max = 2400
Default = 120

Pn7

Ignored

Pn8

Ignored

Ps9

Human Readable

0, 1 : No HRC

Characters

2, 3 , 4 : Print HRC
Ignored for Postnet