E&M Interface Parameter Definitions (cont’d)

Field Name

Values

Description

Dialing Options (cont’d)

Flash Hook Options fields

Generation integer

values,

in

milliseconds

Length of flash hook that will
be generated and sent out when
the remote end initiates a flash
hook and it is regenerated
locally. Default = 600 ms.

Detection
Range

for

Min

.

and

Max

.,

50 1500
milliseconds

For a received flash hook to be
regarded as such by the
MultiVOIP, its duration must
fall between the minimum and
maximum values given here.