Multi-Tech Systems MVP210-SS User Manual

Page 161

Advertising
background image

MultiVOIP User Guide

Technical Configuration

161

Custom Tone-Pair Settings Definitions

Field Name

Values

Description

Cadence 1

integer time
value in
milli-seconds;
zero value for
dial-tone
indicates
continuous tone

On/off pattern of tone durations
used to denote phone ringing,
phone busy, dial tone (“0”
indicates continuous tone)
survivability and re-order.
Cadence 1 is duration of first
period of tone being “on” in the
cadence of the telephony signal
(which could be ring-tone, busy-
tone, unobtainable-tone, or dial
tone).

Cadence 2

duration in
milliseconds

Cadence 2 is duration of first
“off” period in signaling
cadence.

Cadence 3

duration in
milliseconds

Cadence 3 is duration of second
“on” period in signaling cadence.

Cadence 4

duration in
milliseconds

Cadence 4 is duration of second
“off” period in the signaling
cadence, after which the 4-part
cadence pattern of the telephony
signal repeats.



Advertising