background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

35

the +5 V standby output of the power supply. The FPC takes part in implementing the following
system functions:

Power and reset switch interfaces

Fan failure detection

Chassis FRU inventory

System hard reset generation

System power fault indication

ICMB bridge device

Emergency management port (EMP)

LCD interface

3.4.2

Baseboard Management Controller

The baseboard management controller (BMC) on the OPRF100 board set I/O carrier provides
server management monitoring capabilities. Associated with the BMC is a flash memory that
holds the operation code and the BMC configuration defaults. The various server management
functions provided by the BMC are listed below.

Baseboard voltage monitoring

Processor voltage monitoring

Processor voltage ID (VID) monitoring

Processor presence detection

Processor internal error (IERR) and thermal trip monitoring

Fault resilient booting (FRB)

Processor disable control

Watchdog timer

Periodic system management interrupt (SMI) timer

I

2

C master controller

Private management bus interface

System management software (SMS) and SMM IPMB message receiver

Event message receiver

System event log management and access

Sensor data record (SDR) repository management and access

Processor NMI monitoring

Processor SMI monitoring

Time-stamp clock

POST code log