3 hot-swap controller, 5 expansion support, Hot-swap controller – Intel OCPRF100 MP User Manual

Page 43: Expansion support

Advertising
background image

OCPRF100 MP Server System Technical Product Specification
Revision 1.0

36

Secure mode, video blank, and floppy write protect

Front panel NMI monitoring

Software front panel NMI generation

3.4.3

Hot-swap Controller

The hot-swap controller (HSC) on the LVDS SCSI hot-swap backplane is connected to other sys-
tem boards via the IPMB. The HSC provides server management information through both the
IPMB and the SCSI Accessed Fault-Tolerant Enclosures (SAF-TE). SAF-TE is an industry stan-
dard for communicating drive and slot status.

The HSC:

implements the SAF-TE command set accessed through SCSI;

provides an IPMB path for drive presence, drive fault status, backplane temperature, and
fan failure;

controls the fault lights and drive power on the OCPRF100 MP server system chassis
hot-swap backplane;

monitors the power distribution backplane for power supply status; and

controls drive power on and off, facilitating hot-swapping of drives.

3.5

Expansion Support

Table 3-7: OCPRF100 MP Server System Expansion Support summarizes the expansion sup-
port provided by the server system.

Table 3-7: OCPRF100 MP Server System Expansion Support

Quantity

Type

10

64-bit PCI hot-plug expansion bus slots

2

Single connector attachment (SCA-2) SCSI hard disk drive bays

1

5.25-inch half-height drive bays

1

External LVDS connector

32

72-bit SDRAM PC-100 registered DIMM module sockets (16 per memory module)