2 fan requirements, 2 interface requirements, 1 ac inlet connector – Intel OCPRF100 MP User Manual

Page 62: 2 dc output connector(s), Fan requirements, Interface requirements, Ac inlet connector dc output connector(s)

Advertising
background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

55

The power supply dimensions are 5.0" H by 5.3" W by 11.5" D.

5.1.2

Fan Requirements

The power supply incorporates a 120 mm fan for self-cooling. The air comes in from the connec-
tor side, passes through the power supply, and exhausts on the fan side of the power supply.

5.2

Interface Requirements

5.2.1

AC Inlet Connector

The power supply has a standard IEC inlet connector.

5.2.2

DC Output Connector(s)

DC power and control signals are interfaced to the system distribution and control subsystem via
connectors which dock with mating connectors when the power supply is inserted into the system
backplane.

The DC connector is equivalent to the Berg* hybrid 36-pin connector with Intel

®

P/N 703983-001

and Berg P/N 51219-XX002. The pin assignment for the DC connector is shown in Table 5-1:
Connector and Pin Assignments.

Note:

PS_On and PS_Kill are 1.2 mm shorter in mating length compared to other pins in the connector.

Table 5-1: Connector and Pin Assignments

Signal Pins

1

2

3

4

5

6

D

+ 12 V LS

P_Good

AC_OK

+15 V Standby

Remote SEN RTN

- 12 V

C

A0

SCL

FAULT

PRED FAIL

+12 V SENSE

KEY

B

A1

SDA

+3.3 V SENSE

+5 V SENSE

+5 V Stdby

+5 V Stdby

A

+ 3.3 V LS

Power
Present

Spare

+5 V LS

PS_ON

PS_KILL

Power Blades

P1

P2

P3

P4

P5

P6

P7

P8

P9

P10

P11

P12

+12 V

+12 V

GND

GND

GND

GND

GND

GND

+5 V

+5 V

3.3 V

3.3 V

Advertising