5 boot menu, Boot menu – Intel OCPRF100 MP User Manual

Page 92

Advertising
background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

85

NOTES: Default values are marked with the "†" symbol.

6.3.5

Boot Menu

Table 6-17 describes the Boot Menu options, which allow the user to select the boot device. This
table also shows an example list of devices ordered in priority of the boot invocation. Items can
be reprioritized by using the UP and DOWN arrow keys to select the device. Once the device is
selected, use the + (plus) key to move the device higher in the boot priority list. Use the - (minus)
key to move the device lower in the boot priority list.

Table 6-16: Console Redirection Submenu

Feature

Option

?Description

COM Port Address

Disabled†
3F8
2F8
3E8

When enabled, use the I/O port specified.

IRQ #

3†
4

When enabled, use the IRQ specified.

COM Port Baud Rate

9600†
19.2KB
38.4KB
115.2KB

When enabled, use the baud rate specified.
The maximum baud rate supported by the Emergency Man-
agement Port is 19.2K.

Flow Control

No Flow Control
CTS/RTS
XON/XOFF
CTS/RTS + CD†

When enabled, use the flow control type specified.

Table 6-17: Boot Menu

Feature

Option

Description

Floppy Check

Disabled†
Enabled

If Enabled, system will verify floppy type on boot. “Disabled” will
result in a faster boot.

Boot Device Priority

Selects the Boot Device Priority submenu.

Hard Drive

Selects the Hard Drive submenu.

Removable Devices

Selects the Removable Devices submenu.

Removable Format

Selects the Removable Format submenu.

Maximum Number of
I

2

O Drives

1†
4

Selects the maximum number of I

2

O (Intelligent I/O) drives that will

be assigned a DOS drive.

Advertising