3 power good (output), Power good (output) – Intel OCPRF100 MP User Manual

Page 70

Advertising
background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

63

† Measured relative to the power supply DC common output ground pins

5.6.3

Power Good (Output)

Each power supply provides a power good signal. A pin must be allocated for this signal. This
signal indicates that all outputs have reached acceptable operating voltage. The power good sig-
nal levels and sourcing/sinking requirements are shown in Table 5-10: Power Good Signal. The
power good signal is an output signal from the power supply to the system.

† Measured relative to the power supply DC common output ground pins.

The power good signal is held low until all outputs have reached at least 90% of their respective
operating voltages. The turn on delay for the power good signal is between 100 and 1500 milli-
seconds.

The power good signal is low for a minimum of 1 millisecond before any of the output voltages fall
below the regulation limits. Tests are conducted with a maximum load and minimum line voltage.

Table 5-9: AC Good Signal

AC OK Signal

Voltage Level †

Current

LOW: AC is not yet up to the level.

0.4 V max

4 mA min sink current

HIGH: AC is up to the level.

4 V min

0.5 mA max source current

Table 5-10: Power Good Signal

Power Good Signal

Voltage Level †

Current

LOW STATE DE-ASSERTED
(Power Not Good)

0.4 V max

4 mA min sink current

HIGH STATE ASSERTED
(Power Good)

4 V min

0.5 mA max source current

Advertising